The Chinon Flash Meter is used to measure light output from electronic studio flash units or speedlights. This helps photographers calculate the exact aperture (f-stop) needed for a perfect exposure. A flash meter is designed to measure brief bursts of artificial strobe or flash light, whereas a standard light meter measures continuous ambient light.
Key Features:
- The Lumisphere (White Dome): Measures the light falling on the subject from the flash.
- Aperture Scale: The red half-ring arc at the top displays lens aperture values ranging from f/2 to f/22. (2, 2.8, 4, 5.6, 8, 11, 16, 22)
- Film Speed Window (ISO / ASA): The small dial at the bottom allows user to input film or sensor sensitivity.
- Red LED Light: Indicator light flashes or illuminates when a reading is successfully triggered and registered.
How It Works:
1. Set film/sensor speed: Rotate the outer black dial ring until camera's ISO matches the ASA window at the bottom.
2. Position the meter: Place the meter directly in front of subject, pointing the white lumisphere back toward the camera lens (or toward the flash unit to measure).
3. Trigger the flash: Press the button on the side of the meter (often an orange or black button) to arm it, then fire your flash unit.
4. Read the exposure: The physical needle inside the top curved window will jump to point directly at the correct f-stop number. Set camera lens to that exact aperture value.